Export limit exceeded: 23218 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (23218 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-12050 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2024-20496 1 Cisco 2 Sd-wan Vedge Cloud, Sd-wan Vedge Router 2026-04-15 6.1 Medium
A vulnerability in the UDP packet validation code of Cisco SD-WAN vEdge Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition on an affected system. This vulnerability is due to incorrect handling of a specific type of malformed UDP packet. An attacker in a machine-in-the-middle position could exploit this vulnerability by sending crafted UDP packets to an affected device. A successful exploit could allow the attacker to cause the device to reboot, resulting in a DoS condition on the affected system.
CVE-2024-46658 1 Syrotech 1 Sy-gpon-8olt-l3 Firmware 2026-04-15 8 High
Syrotech SY-GOPON-8OLT-L3 v1.6.0_240629 was discovered to contain an authenticated command injection vulnerability.
CVE-2023-5405 1 Honeywell 1 Experion Server 2026-04-15 5.9 Medium
Server information leak for the CDA Server process memory can occur when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2023-5406 2026-04-15 5.9 Medium
Server communication with a controller can lead to remote code execution using a specially crafted message from the controller. See Honeywell Security Notification for recommendations on upgrading and versioning.
CVE-2024-8281 1 Lenovo 139 Thinkagile Hx1021 Edge Certified Node 3yr Firmware, Thinkagile Hx1320 Firmware, Thinkagile Hx1321 Firmware and 136 more 2026-04-15 7.2 High
An input validation weakness was discovered in XCC that could allow a valid, authenticated XCC user with elevated privileges to perform command injection through specially crafted command line input in the XCC SSH captive shell.
CVE-2025-8667 1 Skyworkai 1 Deepresearchagent 2026-04-15 6.3 Medium
A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-47897 2026-04-15 8.8 High
Software installed and run as a non-privileged user may conduct improper GPU system calls resulting in platform instability and reboots.
CVE-2025-12051 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2025-12052 1 Insyde 1 Insydeh2o 2026-04-15 7.8 High
The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow.
CVE-2024-5241 2026-04-15 4.7 Medium
A vulnerability was found in Huashi Private Cloud CDN Live Streaming Acceleration Server up to 20240520. It has been classified as critical. Affected is an unknown function of the file /manager/ipconfig_new.php. The manipulation of the argument dev leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-265992.
CVE-2024-54082 2026-04-15 N/A
home 5G HR02 and Wi-Fi STATION SH-54C contain an OS command injection vulnerability in the configuration restore function. An arbitrary OS command may be executed with the root privilege by an administrative user.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2023-7311 1 Bytevalue 1 Flow Control Router 2026-04-15 N/A
BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).