Search Results (373 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2024-8313 2026-04-15 N/A
An Exposure of Sensitive System Information to an Unauthorized Control Sphere and Initialization of a Resource with an Insecure Default vulnerability in the SNMP component of B&R APROL <4.4-00P5 may allow an unauthenticated adjacent-based attacker to read and alter configuration using SNMP.
CVE-2019-25219 1 Asio 1 Cplusplus Library 2026-04-15 7.5 High
Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used.
CVE-2025-41245 1 Vmware 3 Aria Operations, Cloud Foundation, Tools 2026-04-15 4.9 Medium
VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2024-5801 2026-04-15 N/A
Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2024-47295 1 Seiko Epson Corporation 1 Web Config 2026-04-15 8.1 High
Insecure initial password configuration issue in SEIKO EPSON Web Config allows a remote unauthenticated attacker to set an arbitrary password and operate the device with an administrative privilege. As for the details of the affected versions, see the information provided by the vendor under [References].
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2025-1863 2026-04-15 9.8 Critical
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-41672 1 Wago 1 Device Sphere 2026-04-15 10 Critical
A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices.
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2025-14758 1 Alasca 1 Yaook 2026-04-15 6.5 Medium
Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.