Export limit exceeded: 410207 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (410207 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-27733 | 1 Byzronetwork | 1 Management Platform | 2026-04-15 | 7.7 High |
| File Upload vulnerability in Byzro Network Smart s42 Management Platform v.S42 allows a local attacker to execute arbitrary code via the useratte/userattestation.php component. | ||||
| CVE-2025-11834 | 2 Wiellyam, Wordpress | 2 Wp Ad Gallery, Wordpress | 2026-04-15 | 6.4 Medium |
| The WP AD Gallery plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the 'startindex' parameter of the ad-gallery shortcode in all versions up to, and including, 1.3. This is due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. | ||||
| CVE-2024-36842 | 2026-04-15 | 7.3 High | ||
| An issue in Oncord+ Android Infotainment Systems OS Android 12, Model Hardware TS17,Hardware part Number F57L_V3.2_20220301, and Build Number PlatformVER:K24-2023/05/09-v0.01 allows a remote attacker to execute arbitrary code via the ADB port component. | ||||
| CVE-2024-40762 | 1 Sonicwall | 1 Sonicos | 2026-04-15 | 9.8 Critical |
| Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in the SonicOS SSLVPN authentication token generator that, in certain cases, can be predicted by an attacker potentially resulting in authentication bypass. | ||||
| CVE-2024-43649 | 2026-04-15 | 8.8 High | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2025-11016 | 1 Kalcaddle | 1 Kodbox | 2026-04-15 | 4.3 Medium |
| A security vulnerability has been detected in kalcaddle kodbox up to 1.61.09. The affected element is the function fileOut of the file app/controller/explorer/index.class.php. Such manipulation of the argument path leads to path traversal. The attack may be performed from remote. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-11872 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 6.4 Medium |
| The Material Design Iconic Font Integration plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the plugin's 'mdiconic' shortcode in all versions up to, and including, 2 due to insufficient input sanitization and output escaping on user supplied attributes. This makes it possible for authenticated attackers, with contributor-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. | ||||
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-12080 | 1 Google | 2 Android, Wear Os | 2026-04-15 | N/A |
| On Wear OS devices, when Google Messages is configured as the default SMS/MMS/RCS application, the handling of ACTION_SENDTO intents utilizing the sms:, smsto:, mms:, and mmsto: Uniform Resource Identifier (URI) schemes is incorrectly implemented. Due to this misconfiguration, an attacker capable of invoking an Android intent can exploit this vulnerability to send messages on the user’s behalf to arbitrary receivers without requiring any further user interaction or specific permissions. This allows for the silent and unauthorized transmission of messages from a compromised Wear OS device. | ||||
| CVE-2025-12148 | 1 Search-guard | 1 Search Guard | 2026-04-15 | N/A |
| In Search Guard versions 3.1.1 and earlier, Field Masking (FM) rules are improperly enforced on fields of type IP (IP Address). While the content of these fields is properly redacted in the _source document returned by search operations, the results do return documents (hits) when searching based on a specific IP values. This allows to reconstruct the original contents of the field. Workaround - If you cannot upgrade immediately, you can avoid the problem by using field level security (FLS) protection on fields of the affected types instead of field masking. | ||||
| CVE-2024-43648 | 2026-04-15 | 8.8 High | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-37862 | 1 Open Robotic | 3 Navigation2 Humble, Ros2 Humble, Ros2 Navigation2 | 2026-04-15 | 7.3 High |
| Buffer Overflow vulnerability in Open Robotic Robotic Operating System 2 ROS2 navigation2- ROS2-humble&& navigation2-humble allows a local attacker to execute arbitrary code via a crafted .yaml file to the nav2_planner process. | ||||
| CVE-2025-22369 | 2026-04-15 | N/A | ||
| The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS. | ||||
| CVE-2025-22368 | 2026-04-15 | N/A | ||
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. | ||||
| CVE-2025-22367 | 2026-04-15 | N/A | ||
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. | ||||
| CVE-2025-2230 | 2026-04-15 | 7.7 High | ||
| A flaw exists in the Windows login flow where an AuthContext token can be exploited for replay attacks and authentication bypass. | ||||
| CVE-2025-9164 | 2 Docker, Microsoft | 3 Desktop, Docker Desktop, Windows | 2026-04-15 | N/A |
| Docker Desktop Installer.exe is vulnerable to DLL hijacking due to insecure DLL search order. The installer searches for required DLLs in the user's Downloads folder before checking system directories, allowing local privilege escalation through malicious DLL placement.This issue affects Docker Desktop: through 4.48.0. | ||||
