Search Results (29535 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-3657 1 Redhat 5 Directory Server, Directory Server E4s, Directory Server Eus and 2 more 2026-04-15 7.5 High
A flaw was found in 389-ds-base. A specially-crafted LDAP query can potentially cause a failure on the directory server, leading to a denial of service
CVE-2025-9060 1 Msoft 1 Mflash 2026-04-15 9.1 Critical
A vulnerability has been found in the  MSoft MFlash application that allows execution of arbitrary code on the server. The issue occurs in the integration configuration functionality that is only available to MFlash administrators. The vulnerability is related to insufficient validation of parameters when setting up security components. This issue affects MFlash v. 8.0 and possibly others. To mitigate apply 8.2-653 hotfix 11.06.2025 and above.
CVE-2025-9036 1 Rockwellautomation 1 Factorytalk Action Manager 2026-04-15 N/A
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection.
CVE-2025-27211 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
CVE-2025-8866 1 Yugabyte 1 Yugabytedb 2026-04-15 5.3 Medium
YugabyteDB Anywhere web server does not properly enforce authentication for the /metamaster/universe API endpoint. An unauthenticated attacker could exploit this flaw to obtain server networking configuration details, including private and public IP addresses and DNS records.
CVE-2025-8862 1 Yugabyte 1 Yugabytedb 2026-04-15 3.1 Low
YugabyteDB has been collecting diagnostics information from YugabyteDB servers, which may include sensitive gflag configurations. To mitigate this, we recommend upgrading the database to a version where this information is properly redacted.
CVE-2025-48490 2026-04-15 N/A
Laravel Rest Api is an API generator. Prior to version 2.13.0, a validation bypass vulnerability was discovered where multiple validations defined for the same attribute could be silently overridden. Due to how the framework merged validation rules across multiple contexts (such as index, store, and update actions), malicious actors could exploit this behavior by crafting requests that bypass expected validation rules, potentially injecting unexpected or dangerous parameters into the application. This could lead to unauthorized data being accepted or processed by the API, depending on the context in which the validation was bypassed. This issue has been patched in version 2.13.0.
CVE-2025-54564 1 Chargepoint 1 Home Flex 2026-04-15 7.8 High
uploadsm in ChargePoint Home Flex 5.5.4.13 does not validate a user-controlled string for bz2 decompression, which allows command execution as the nobody user.
CVE-2025-20290 1 Cisco 8 Nexus, Nexus 3000, Nexus 9000 and 5 more 2026-04-15 5.5 Medium
A vulnerability in the logging feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches, Cisco Nexus 9000 Series Switches in standalone NX-OS mode, Cisco UCS 6400 Fabric Interconnects, Cisco UCS 6500 Series Fabric Interconnects, and Cisco UCS 9108 100G Fabric Interconnects could allow an authenticated, local attacker access to sensitive information. This vulnerability is due to improper logging of sensitive information. An attacker could exploit this vulnerability by accessing log files on the file system where they are stored. A successful exploit could allow the attacker to access sensitive information, such as stored credentials.
CVE-2024-11106 1 Wpchill 1 Simple Restrict 2026-04-15 5.3 Medium
The Simple Restrict plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 1.2.7 via the WordPress core search feature. This makes it possible for unauthenticated attackers to extract sensitive data from posts that have been restricted to higher-level roles such as administrator.
CVE-2024-13567 2026-04-15 7.5 High
The Awesome Support – WordPress HelpDesk & Support Plugin plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 6.3.1 via the 'awesome-support' directory. This makes it possible for unauthenticated attackers to extract sensitive data stored insecurely in the /wp-content/uploads/awesome-support directory which can contain file attachments included in support tickets. The vulnerability was partially patched in version 6.3.1.
CVE-2025-11273 1 Lachatterie 1 Verger 2026-04-15 6.3 Medium
A vulnerability was found in LaChatterie Verger up to 1.2.10. This impacts the function redirectToAuthorization of the file /src/main/services/mcp/oauth/provider.ts. The manipulation of the argument URL results in deserialization. The attack can be executed remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-22453 1 Intel 1 Server Firmware Update Utility 2026-04-15 7.5 High
Improper input validation for some Server Firmware Update Utility(SysFwUpdt) before version 16.0.12 within Ring 3: User Applications may allow an escalation of privilege. System software adversary with a privileged user combined with a high complexity attack may enable local code execution. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-27212 2 Ubiquiti, Ui 5 Unifi Access Points, Unifi Os, Intercom and 2 more 2026-04-15 9.8 Critical
An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later
CVE-2025-27387 1 Oppo 1 Oppo Clone Phone 2026-04-15 7.4 High
OPPO Clone Phone uses a weak password WiFi hotspot to transfer files, resulting in Information disclosure.
CVE-2025-29781 1 Redhat 1 Openshift 2026-04-15 6.5 Medium
The Bare Metal Operator (BMO) implements a Kubernetes API for managing bare metal hosts in Metal3. Baremetal Operator enables users to load Secret from arbitrary namespaces upon deployment of the namespace scoped Custom Resource `BMCEventSubscription`. Prior to versions 0.8.1 and 0.9.1, an adversary Kubernetes account with only namespace level roles (e.g. a tenant controlling a namespace) may create a `BMCEventSubscription` in his authorized namespace and then load Secrets from his unauthorized namespaces to his authorized namespace via the Baremetal Operator, causing Secret Leakage. The patch makes BMO refuse to read Secrets from other namespace than where the corresponding BMH resource is. The patch does not change the `BMCEventSubscription` API in BMO, but stricter validation will fail the request at admission time. It will also prevent the controller reading such Secrets, in case the BMCES CR has already been deployed. The issue exists for all versions of BMO, and is patched in BMO releases v0.9.1 and v0.8.1. Prior upgrading to patched BMO version, duplicate any existing Secret pointed to by `BMCEventSubscription`'s `httpHeadersRef` to the same namespace where the corresponding BMH exists. After upgrade, remove the old Secrets. As a workaround, the operator can configure BMO RBAC to be namespace scoped, instead of cluster scoped, to prevent BMO from accessing Secrets from other namespaces, and/or use `WATCH_NAMESPACE` configuration option to limit BMO to single namespace.
CVE-2025-7693 1 Rockwellautomation 1 Micro800 2026-04-15 N/A
A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF015. To recover, clear the fault.
CVE-2025-7674 1 Roche 1 Navify Monitoring 2026-04-15 N/A
Improper Input Validation vulnerability in Roche Diagnostics navify Monitoring allows an attacker to manipulate input data, which may lead to a denial of service (DoS) due to negatively impacting the server's performance. This vulnerability has no impact on data confidentiality or integrity. This issue affects navify Monitoring before 1.08.00.
CVE-2025-59427 1 Cloudflare 2 Vite, Workerd 2026-04-15 N/A
The Cloudflare Vite plugin enables a full-featured integration between Vite and the Workers runtime. When utilising the Cloudflare Vite plugin in its default configuration, all files are exposed by the local dev server, including files in the root directory that contain secret information such as .env and .dev.vars. This vulnerability is fixed in 1.6.0.
CVE-2025-7573 2026-04-15 5.3 Medium
A vulnerability, which was classified as critical, has been found in LB-LINK BL-AC1900, BL-AC2100_AZ3, BL-AC3600, BL-AX1800, BL-AX5400P and BL-WR9000 up to 20250702. This issue affects the function bs_GetManPwd in the library libblinkapi.so of the file /cgi-bin/lighttpd.cgi. The manipulation leads to information disclosure. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.