| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SAP Replication Server allows an attacker to use gateway for executing some commands to RSSD. This could result in crashing the Replication Server due to memory corruption with high impact on Availability of the system. |
| Out-Of-Bounds Write, Use of Uninitialized Resource and Use-After-Free vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted SLDDRW or SLDPRT file. NOTE: this vulnerability was SPLIT from CVE-2024-1847. |
| Out-Of-Bounds Write and Type Confusion vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted DWG or DXF. NOTE: this vulnerability was SPLIT from CVE-2024-1847. |
| Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege. |
| The specific function parameter of ASUS Download Master does not properly filter user input. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device. |
| A remote attacker with high privileges may use a deleting file function to inject OS commands.
|
| A remote attacker with high privileges may use a writing file function to inject OS commands.
|
| A remote attacker with high privileges may use a reading file function to inject OS commands.
|
| Remote Command program allows an attacker to get Remote Code Execution. As for the affected products/models/versions, see the reference URL. |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent unauthenticated attacker to execute arbitrary OS commands by sending a specially crafted request to the product. Affected products and versions are as follows: WRC-X3200GST3-B v1.25 and earlier, WRC-G01-W v1.24 and earlier, and WMC-X1800GST-B v1.41 and earlier. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B". |
| Command Injection in the diagnostics interface of the Bosch Network Synchronizer allows unauthorized users full access to the device. |
| A flaw was found in the RPC library APIs of libvirt. The RPC server deserialization code allocates memory for arrays before the non-negative length check is performed by the C API entry points. Passing a negative length to the g_new0 function results in a crash due to the negative length being treated as a huge positive number. This flaw allows a local, unprivileged user to perform a denial of service attack by causing the libvirt daemon to crash. |
| Command injection vulnerability in Movistar 4G router affecting version ES_WLD71-T1_v2.0.201820. This vulnerability allows an authenticated user to execute commands inside the router by making a POST request to the URL '/cgi-bin/gui.cgi'. |
| A vulnerability in the UDP packet validation code of Cisco SD-WAN vEdge Software could allow an unauthenticated, adjacent attacker to cause a denial of service (DoS) condition on an affected system.
This vulnerability is due to incorrect handling of a specific type of malformed UDP packet. An attacker in a machine-in-the-middle position could exploit this vulnerability by sending crafted UDP packets to an affected device. A successful exploit could allow the attacker to cause the device to reboot, resulting in a DoS condition on the affected system. |
| Certain ASUS WiFi routers models has an OS Command Injection vulnerability, allowing an authenticated remote attacker to execute arbitrary system commands by sending a specially crafted request. |
| OS command injection vulnerabilities in GE HealthCare ultrasound devices |
| A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A heap-based memory vulnerability has been identified in the Postscript interpreter in various Lexmark devices. The vulnerability can be leveraged by an attacker to execute arbitrary code. |
| IDExpert from CHANGING Information Technology does not properly validate a specific parameter in the administrator interface, allowing remote attackers with administrative privileges to inject and execute OS commands on the server. |
| SECOM WRTR-304GN-304TW-UPSC does not properly filter user input in the specific functionality. Unauthenticated remote attackers can exploit this vulnerability to inject and execute arbitrary system commands on the device. |