Search

Search Results (408108 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-63353 2026-10-13 9.6 Critical
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-63354 2026-10-13 9.6 Critical
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.
CVE-2026-109153 1 Mosaicml 1 Composer 2026-10-13 6.3 Medium
A vulnerability was detected in MosaicML Composer up to 0.32.1. This affects the function tarball.extractall of the file composer/utils/checkpoint.py of the component Checkpoint Extraction. The manipulation results in path traversal. The attack can be executed remotely. The vendor was contacted early about this disclosure.
CVE-2026-109149 1 Beautifier 1 Js-beautify 2026-10-13 5.3 Medium
A weakness has been identified in beautifier js-beautify up to 1.15.1/2.0.3. The affected element is an unknown function. Executing a manipulation can lead to uncontrolled memory allocation. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-41125 1 Siemens 29 Blueplanet 100 Nx3 M8, Blueplanet 100 Tl3 Gen2, Blueplanet 105 Tl3 and 26 more 2026-10-13 6 Medium
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsave 110 TL3-S (All versions < V3.92), blueplanet gridsave 137 TL3-S (All versions < V3.92), blueplanet gridsave 92.0 TL3-S (All versions < V3.92). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.
CVE-2025-40817 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 6.5 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently.
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2025-40815 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.2 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2025-40759 2026-10-13 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-10-13 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-52051 2026-10-13 7.3 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.
CVE-2024-49849 2026-10-13 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2026-109143 1 Calcom 2 Cal.com, Cal.diy 2026-10-13 5.4 Medium
A vulnerability was determined in calcom cal.com and cal.diy up to 6.2.0. This vulnerability affects the function credentials.delete of the file /api/trpc/credentials/delete of the component Credentials Handler. This manipulation of the argument teamId causes improper privilege management. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-96535 1 Youmind 1 Youmind Web Application 2026-10-13 N/A
Cross-Site Scripting on the YouMind portal, specifically in the avatar update endpoint, when setting a profile picture via an arbitrary URL. This occurs due to a lack of sanitisation and validation of SVG content when setting an SVG image containing embedded JavaScript code as the avatar. The file is served by the CDN with Content-Type: image/svg+xml and, when navigating directly to that URL, the script executes within the context of the CDN’s domain.
CVE-2026-13138 2026-10-13 8.6 High
Client-Side Enforcement of Server-Side Security vulnerability in Divasoft Software and E-Commerce Inc. Biletiva Ticketing Platform allows Manipulating State. This issue affects Biletiva Ticketing Platform: through 2026-07-23.
CVE-2026-109115 1 Adithyayelloju 1 Restaurant-management-system 2026-10-13 7.3 High
A vulnerability was found in AdithyaYelloju Restaurant-Management-System up to 7f0e7e84255e8fcfd488e83f8f91451bbbff6b9c. This issue affects some unknown processing of the file User/forgot3.php of the component Password Reset. Performing a manipulation of the argument email/password results in sql injection. The attack can be initiated remotely. The exploit has been made public and could be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The project was informed of the problem early through an issue report but has not responded yet.
CVE-2026-109110 1 Wavlink 1 Wl-wn592ax6 2026-10-13 10 Critical
A flaw has been found in Wavlink WL-WN592AX6 250422. This issue affects the function system of the component wmapd Daemon. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure.
CVE-2026-108718 1 Rill Data 1 Rill 2026-10-13 8.1 High
Rill 0.77.0 through 0.90.5 contains a missing authorization vulnerability in the admin OAuth server that issues authorization codes to dynamically registered clients without user consent. Attackers can register a client with the long_lived_access_token scope and lure a user to an authorization link, obtaining a non-expiring API token with the user's full permissions.
CVE-2026-108723 1 Qingyuna 1 Answer-me-with-html 2026-10-13 2.5 Low
answer-me-with-html through 0.5.0 contains a link following vulnerability in the am CLI code block src= embedding, where localPath() checks only path text without resolving symlinks. Attackers can ship a repository with a symlink pointing outside the checkout so am render embeds readable external files into generated HTML, disclosing them when shared.
CVE-2026-108728 1 Flyteorg 1 Flyte 2026-10-13 6.5 Medium
Flyte 2.0.1 through 2.0.51 contains a cleartext secret storage vulnerability that allows users with Pod read access to obtain secrets by reading init container environment variables. The embedded secret manager webhook writes base64-encoded FILE-mounted secret values into the SECRETS environment variable, letting principals without Secret store access decode them from the Pod spec.