Search Results (979 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-10601 1 Juniper 1 Junos 2025-04-20 N/A
A specific device configuration can result in a commit failure condition. When this occurs, a user is logged in without being prompted for a password while trying to login through console, ssh, ftp, telnet or su, etc., This issue relies upon a device configuration precondition to occur. Typically, device configurations are the result of a trusted administrative change to the system's running configuration. The following error messages may be seen when this failure occurs: mgd: error: commit failed: (statements constraint check failed) Warning: Commit failed, activating partial configuration. Warning: Edit the router configuration to fix these errors. If the administrative changes are not made that result in such a failure, then this issue is not seen. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.3 prior to 12.3R10, 12.3R11; 12.3X48 prior to 12.3X48-D20; 13.2 prior to 13.2R8; 13.3 prior to 13.3R7; 14.1 prior to 14.1R4-S12, 14.1R5, 14.1R6; 14.1X53 prior to 14.1X53-D30; 14.2 prior to 14.2R4; 15.1 prior to 15.1F2, 15.1F3, 15.1R2.
CVE-2017-10624 1 Juniper 1 Junos Space 2025-04-20 N/A
Insufficient verification of node certificates in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to make unauthorized modifications to Space database or add nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1.
CVE-2017-10623 1 Juniper 1 Junos Space 2025-04-20 N/A
Lack of authentication and authorization of cluster messages in Juniper Networks Junos Space may allow a man-in-the-middle type of attacker to intercept, inject or disrupt Junos Space cluster operations between two nodes. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1.
CVE-2017-10622 1 Juniper 1 Junos Space 2025-04-20 N/A
An authentication bypass vulnerability in Juniper Networks Junos Space Network Management Platform may allow a remote unauthenticated network based attacker to login as any privileged user. This issue only affects Junos Space Network Management Platform 17.1R1 without Patch v1 and 16.1 releases prior to 16.1R3. This issue was found by an external security researcher.
CVE-2017-10614 1 Juniper 1 Junos 2025-04-20 N/A
A vulnerability in telnetd service on Junos OS allows a remote attacker to cause a limited memory and/or CPU consumption denial of service attack. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D45; 12.3X48 prior to 12.3X48-D30; 14.1 prior to 14.1R4-S9, 14.1R8; 14.2 prior to 14.2R6; 15.1 prior to 15.1F5, 15.1R3; 15.1X49 prior to 15.1X49-D40; 15.1X53 prior to 15.1X53-D232, 15.1X53-D47.
CVE-2016-4925 1 Juniper 1 Junose 2025-04-20 N/A
Receipt of a specifically malformed IPv6 packet processed by the router may trigger a line card reset: processor exception 0x68616c74 (halt) in task: scheduler. The line card will reboot and recover without user interaction. However, additional specifically malformed packets may cause follow-on line card resets and lead to an extended service outage. This issue only affects E Series routers with IPv6 licensed and enabled. Routers not configured to process IPv6 traffic are unaffected by this vulnerability. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue.
CVE-2016-4924 1 Juniper 1 Junos 2025-04-20 N/A
An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8
CVE-2016-4921 1 Juniper 1 Junos 2025-04-20 N/A
By flooding a Juniper Networks router running Junos OS with specially crafted IPv6 traffic, all available resources can be consumed, leading to the inability to store next hop information for legitimate traffic. In extreme cases, the crafted IPv6 traffic may result in a total resource exhaustion and kernel panic. The issue is triggered by traffic destined to the router. Transit traffic does not trigger the vulnerability. This issue only affects devices with IPv6 enabled and configured. Devices not configured to process IPv6 traffic are unaffected by this vulnerability. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. Affected releases are Juniper Networks Junos OS 11.4 prior to 11.4R13-S3; 12.3 prior to 12.3R3-S4; 12.3X48 prior to 12.3X48-D30; 13.3 prior to 13.3R10, 13.3R4-S11; 14.1 prior to 14.1R2-S8, 14.1R4-S12, 14.1R8; 14.1X53 prior to 14.1X53-D28, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R3-S10, 14.2R4-S7, 14.2R6; 15.1 prior to 15.1F2-S5, 15.1F5-S2, 15.1F6, 15.1R3; 15.1X49 prior to 15.1X49-D40; 15.1X53 prior to 15.1X53-D57, 15.1X53-D70.
CVE-2016-4926 1 Juniper 1 Junos Space 2025-04-20 N/A
Insufficient authentication vulnerability in Junos Space before 15.2R2 allows remote network based users with access to Junos Space web interface to perform certain administrative tasks without authentication.
CVE-2017-10610 1 Juniper 2 Junos, Srx Series 2025-04-20 N/A
On SRX Series devices, a crafted ICMP packet embedded within a NAT64 IPv6 to IPv4 tunnel may cause the flowd process to crash. Repeated crashes of the flowd process constitutes an extended denial of service condition for the SRX Series device. This issue only occurs if NAT64 is configured. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D71, 12.3X48 prior to 12.3X48-D55, 15.1X49 prior to 15.1X49-D100 on SRX Series. No other Juniper Networks products or platforms are affected by this issue.
CVE-2016-7103 7 Debian, Fedoraproject, Jqueryui and 4 more 13 Debian Linux, Fedora, Jquery Ui and 10 more 2025-04-20 6.1 Medium
Cross-site scripting (XSS) vulnerability in jQuery UI before 1.12.0 might allow remote attackers to inject arbitrary web script or HTML via the closeText parameter of the dialog function.
CVE-2016-4927 1 Juniper 1 Junos Space 2025-04-20 N/A
Insufficient validation of SSH keys in Junos Space before 15.2R2 allows man-in-the-middle (MITM) type of attacks while a Space device is communicating with managed devices.
CVE-2016-1265 1 Juniper 1 Junos Space 2025-04-20 N/A
A remote unauthenticated network based attacker with access to Junos Space may execute arbitrary code on Junos Space or gain access to devices managed by Junos Space using cross site request forgery (CSRF), default authentication credentials, information leak and command injection attack vectors. All versions of Juniper Networks Junos Space prior to 15.1R3 are affected.
CVE-2017-2313 1 Juniper 1 Junos 2025-04-20 N/A
Juniper Networks devices running affected Junos OS versions may be impacted by the receipt of a crafted BGP UPDATE which can lead to an rpd (routing process daemon) crash and restart. Repeated crashes of the rpd daemon can result in an extended denial of service condition. The affected Junos OS versions are: 15.1 prior to 15.1F2-S15, 15.1F5-S7, 15.1F6-S5, 15.1F7, 15.1R4-S7, 15.1R5-S2, 15.1R6; 15.1X49 prior to 15.1X49-D78, 15.1X49-D80; 15.1X53 prior to 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 prior to 16.1R3-S3, 16.1R4; 16.2 prior to 16.2R1-S3, 16.2R2; Releases prior to Junos OS 15.1 are unaffected by this vulnerability. 17.1R1, 17.2R1, and all subsequent releases have a resolution for this vulnerability.
CVE-2017-2315 1 Juniper 1 Junos 2025-04-20 N/A
On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability.
CVE-2016-4931 1 Juniper 1 Junos Space 2025-04-20 N/A
XML entity injection in Junos Space before 15.2R2 allows attackers to cause a denial of service.
CVE-2017-2304 1 Juniper 7 Ex4300, Ex4600, Junos and 4 more 2025-04-20 N/A
Juniper Networks QFX3500, QFX3600, QFX5100, QFX5200, EX4300 and EX4600 devices running Junos OS 14.1X53 prior to 14.1X53-D40, 15.1X53 prior to 15.1X53-D40, 15.1 prior to 15.1R2, do not pad Ethernet packets with zeros, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak'
CVE-2017-2305 1 Juniper 1 Junos Space 2025-04-20 N/A
On Juniper Networks Junos Space versions prior to 16.1R1, due to an insufficient authorization check, readonly users on the Junos Space administrative web interface can create privileged users, allowing privilege escalation.
CVE-2017-2303 1 Juniper 1 Junos 2025-04-20 N/A
On Juniper Networks products or platforms running Junos OS 12.1X46 prior to 12.1X46-D50, 12.1X47 prior to 12.1X47-D40, 12.3 prior to 12.3R13, 12.3X48 prior to 12.3X48-D30, 13.2X51 prior to 13.2X51-D40, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D35, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R5, 15.1 prior to 15.1F6 or 15.1R3, 15.1X49 prior to 15.1X49-D30 or 15.1X49-D40, 15.1X53 prior to 15.1X53-D35, and where RIP is enabled, certain RIP advertisements received by the router may cause the RPD daemon to crash resulting in a denial of service condition.
CVE-2017-2312 1 Juniper 1 Junos 2025-04-20 N/A
On Juniper Networks devices running Junos OS affected versions and with LDP enabled, a specific LDP packet destined to the RE (Routing Engine) will consume a small amount of the memory allocated for the rpd (routing protocol daemon) process. Over time, repeatedly receiving this type of LDP packet(s) will cause the memory to exhaust and the rpd process to crash and restart. It is not possible to free up the memory that has been consumed without restarting the rpd process. This issue affects Junos OS based devices with either IPv4 or IPv6 LDP enabled via the [protocols ldp] configuration (the native IPv6 support for LDP is available in Junos OS 16.1 and higher). The interface on which the packet arrives needs to have LDP enabled. The affected Junos versions are: 13.3 prior to 13.3R10; 14.1 prior to 14.1R8; 14.2 prior to 14.2R7-S6 or 14.2R8; 15.1 prior to 15.1F2-S14, 15.1F6-S4, 15.1F7, 15.1R4-S7, 15.1R5; 15.1X49 before 15.1X49-D70; 15.1X53 before 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 before 16.1R2. 16.2R1 and all subsequent releases have a resolution for this vulnerability.