| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| EasyFlow GP developed by Digiwin has an Insufficiently Protected Credentials vulnerability, allowing privileged remote attackers to obtain plaintext database account credentials from the system frontend. |
| This vulnerability allows an attacker to access parts of the application that are not protected by any type of access control. The attacker could access this path ‘…/epsilonnet/License/About.aspx’ and obtain information on both the licence and the configuration of the product by knowing which modules are installed. |
| In SAP NetWeaver Java (Software Update Manager 1.1), under certain conditions when a software upgrade encounters errors, credentials are written in plaintext to a log file. An attacker with local access to the server, authenticated as a non-administrative user, can acquire the credentials from the logs. This leads to a high impact on confidentiality, with no impact on integrity or availability. |
| Cryptographic key extraction from internal flash in Minut M2 with firmware version #15142 allows physically proximate attackers to inject modified firmware into any other Minut M2 product via USB. |
| Kieback & Peter's DDC4000 series has an insufficiently protected credentials vulnerability, which may allow an unauthenticated attacker with access to /etc/passwd to read the password hashes of all users on the system. |
| GRAU DATA Blocky before 3.1 stores passwords encrypted rather than hashed. At the login screen, the user's password is compared to the user's decrypted cleartext password. An attacker with Windows admin or debugging rights can therefore steal the user's Blocky password and from there impersonate that local user. |
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. |
| Logs storing credentials are insufficiently protected and can be decoded through the use of open source tools. |
| Utilizing default credentials, an attacker is able to log into the camera's operating system which could allow changes to be made to the operations or shutdown the camera requiring a physical reboot of the system. |
| apko is an apk-based OCI image builder. apko exposures HTTP basic auth credentials from repository and keyring URLs in log output. This vulnerability is fixed in v0.14.5. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.1.0.0 and 9.3.0.8, including 8.3.x, discloses database passwords when searching metadata injectable fields. |
| The /WmAdmin/,/invoke/vm.server/login login page in the Integration Server in Software AG webMethods 10.15.0 before Core_Fix7 allows remote attackers to reach the administration panel and discover hostname and version information by sending an arbitrary username and a blank password to the /WmAdmin/#/login/ URI. |
| With address book access, SMB/FTP settings could be modified, redirecting scans and possibly capturing credentials. This requires enabled scan functions and printer access. |
| Insufficient access checks in Visual Planning Admin Center 8 before v.1 Build 240207 allow attackers in possession of a non-administrative Visual Planning account to utilize functions normally reserved for administrators. The affected functions allow attackers to obtain different types of configured credentials and potentially elevate their privileges to administrator level. |
| A vulnerability has been identified in the way that Rancher stores vSphere's CPI (Cloud Provider Interface) and CSI (Container Storage Interface) credentials used to deploy clusters through the vSphere cloud provider. This issue leads to the vSphere CPI and CSI passwords being stored in a plaintext object inside Rancher. This vulnerability is only applicable to users that deploy clusters in vSphere environments. |
| The webserver utilizes basic authentication for its user login to the configuration interface. As encryption is disabled on port 80, it enables potential eavesdropping on user traffic, making it possible to intercept their credentials. |
| Trivy is a security scanner. Prior to 0.51.2, if a malicious actor is able to trigger Trivy to scan container images from a crafted malicious registry, it could result in the leakage of credentials for legitimate registries such as AWS Elastic Container Registry (ECR), Google Cloud Artifact/Container Registry, or Azure Container Registry (ACR). These tokens can then be used to push/pull images from those registries to which the identity/user running Trivy has access. Systems are not affected if the default credential provider chain is unable to obtain valid credentials. This vulnerability only applies when scanning container images directly from a registry. This vulnerability is fixed in 0.51.2. |
| Asus RT-N12+ B1 router stores credentials in cleartext, which could allow local attackers to obtain unauthorized access and modify router settings. |
| NuCom 11N Wireless Router 5.07.90 contains a privilege escalation vulnerability that allows non-privileged users to access administrative credentials through the configuration backup endpoint. Attackers can send a crafted HTTP GET request to the backup configuration page with a specific cookie to retrieve and decode the admin password in Base64 format. |